ProductsAbaqus/Explicit TypeModel data
LevelPartPart instance
Required parameters
- MAXIMUM NUMBER OF PARTICLES
-
Set this parameter equal to an upper bound of the maximum number of
particles expected to be generated during the analysis.
- NAME
-
Set this parameter equal to the name of the particle generator.
- TYPE
-
Set this parameter equal to the type of particle to be generated. PD3D and PC3D elements are supported.

Optional parameters
- MAX ATTEMPTS PER INCREMENT
-
Set this parameter equal to the maximum number of particle insertion attempt
cycles the generator makes before halting generation for an increment. The
default value is 10.
- MAX INSERTION ATTEMPTS
-
Set this parameter equal to the maximum number of attempts the generator
makes to place a particle of a given size before rejecting that particle size.
The default value is 15.
- SOLID FRACTION
-
Set this parameter equal to a threshold value that will temporarily halt the
particle generator for an increment if the region near the inlet has a high
volume of particles. The threshold value is a particle volume fraction over a
volume that extends
in front of the inlet surface, where
is the maximum particle radius for the generator. The default value is 0.4.

There are no data lines associated with this option.
|