ProductsAbaqus/Standard
TypeModel data
LevelPartPart instanceAssembly
Required parameters
- ELSET
- Set this parameter equal to the name
of the element set containing the elements that will be activated during the
analysis.
- NAME
- Set this parameter equal to a label
that will be used to refer to this progressive element
activation.
Optional parameters
- FOLLOW DEFORMATION
-
Set FOLLOW DEFORMATION=NO (default) for elements that have not yet been activated to
remain in their initial positions.
Set FOLLOW DEFORMATION=YES for elements that have not yet been activated to follow the
movement of the active elements to prevent their excessive deformation.
- FREE SURFACE
-
Set FREE SURFACE=NONE (default) for convection or radiation boundary conditions to
be applied on the full exposed areas of the element facets. If the element is
partially filled, the cooling is applied on the full element facet area.
Set FREE SURFACE=FACET for user subroutine
UEPACTIVATIONFACET to be
called at the start of the increment for each element. You can prescribe the
facet area and the increment time for which the facet area is exposed for
cooling. You can prescribe the exposed areas on the element facets and the
internal cut facet for partial element activation. This feature is supported
only for lower-order elements.
There are no data lines associated with this option.