ProductsAbaqus/Standard TypeHistory data
LevelStep
Required parameters
- ACTIVATION
- Set this parameter equal to the name
assigned to the progressive element activation feature on the
ELEMENT PROGRESSIVE ACTIVATION
option.
Optional parameters
- EXPANSION TIME CONSTANT
- Set this parameter equal to the time
constant used to ramp on thermal strains at element activation. The default
value is 2 times the initial time
increment.
Data lines to
define progressive element activation - First (and only)
line
-
-
Table collection name.
|