- LOW FREQUENCY CUTOFF
This parameter is relevant for transient modal analysis only.
Set this parameter equal to the frequency value below which the eigenmodes
will not be damped even if damping is requested at the material, element,
and/or modal level. This parameter is useful for free structures or for models
with secondary base motions.
If this parameter is omitted, the default value is used. The default value
is six orders of magnitude smaller than the frequency of the first deformable
eigenmode.
If this parameter is included but no value is given, the low frequency
cutoff value is given as the square root of the platform precision value.
A negative value can be assigned to allow damping at the low frequency
modes.
The parameter units are cycles/time.
- STRUCTURAL
Set this parameter equal to ELEMENT to request the structural damping matrix that includes
material and/or element damping properties only.
Set this parameter equal to FACTOR to request the structural damping matrix that includes the
global damping factor only.
Set this parameter equal to COMBINED to request the structural damping matrix that includes the
combination of both ELEMENT and FACTOR.
Set this parameter equal to NONE to exclude the structural damping matrix at this step.
If this parameter is omitted or the option is not used within the step
definition, the default uses all structural damping specified at the model and
step levels. If both material and global structural damping are specified, the COMBINED damping is used.
If this parameter is omitted or the option is not used as a suboption of
SUBSTRUCTURE PROPERTY, the substructure property uses COMBINED as the default with the structural factor specified under the
DAMPING, STRUCTURAL option.
- VISCOUS
Set this parameter equal to ELEMENT to request a viscous damping matrix that includes material
and/or element damping properties only.
Set this parameter equal to FACTOR to request a viscous damping matrix that includes the global
damping factor only.
Set this parameter equal to COMBINED to request a viscous damping matrix that includes a
combination of ELEMENT and FACTOR.
Set this parameter equal to NONE to exclude the viscous damping matrix in this step.
If this parameter is omitted or the option is not used within the step
definition, the default uses all viscous damping specified at the model and
step levels. If both material and global damping are specified, the COMBINED damping is used.
If this parameter is omitted or the option is not used as a suboption of
SUBSTRUCTURE PROPERTY, the substructure property uses COMBINED as the default with the mass and stiffness proportional
Rayleigh damping factors specified under the
DAMPING, ALPHA or BETA option.