- allowPropagation
A Boolean specifying whether to allow all control values to propagate from a previous step. Setting this argument to ON automatically sets resetDefaultValues to OFF. The default value is ON.
- resetDefaultValues
A Boolean specifying whether to use all default control values. Setting this argument to ON automatically sets allowPropagation to OFF. The default value is OFF.
- discontinuous
A Boolean specifying whether to set timeIncrementation values that will usually improve efficiency for analyses with severely discontinuous behavior. The default value is OFF.
- constraints
The SymbolicConstant DEFAULT or a sequence of Floats specifying tolerances on constraint equations. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- lineSearch
The SymbolicConstant DEFAULT or a sequence of Floats specifying line search control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- timeIncrementation
The SymbolicConstant DEFAULT or a sequence of Floats specifying time incrementation control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- directCyclic
The SymbolicConstant DEFAULT or a sequence of Floats specifying direct cyclic control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- concentrationField
The SymbolicConstant DEFAULT or a sequence of Floats specifying mass concentration field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- displacementField
The SymbolicConstant DEFAULT or a sequence of Floats specifying displacement field and warping degree of freedom field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- electricalPotentialField
The SymbolicConstant DEFAULT or a sequence of Floats specifying electrical potential field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- globalField
The SymbolicConstant DEFAULT or a sequence of Floats specifying parameters for all applicable field equilibrium equations. This argument overwrites all other field equilibrium equation control values. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- hydrostaticFluidPressureField
The SymbolicConstant DEFAULT or a sequence of Floats specifying hydrostatic fluid element volume constraint parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- poreFluidPressureField
The SymbolicConstant DEFAULT or a sequence of Floats specifying pore liquid volumetric continuity equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- rotationField
The SymbolicConstant DEFAULT or a sequence of Floats specifying rotation field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- temperatureField
The SymbolicConstant DEFAULT or a sequence of Floats specifying temperature field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.
- vcctLinearScaling
The SymbolicConstant DEFAULT or a Float specifying linear scaling parameter for a VCCT debonding analysis. If a specified value is 0, it will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT.