*HEADING CANTILEVER WITH SHELL ELEMENTS--END SHEAR, S4R, 8 X 16 MESH EXPLICIT ANALYSIS WITH ENHANCED HOURGLASS CONTROL *NODE 1,0.,0. 33,6.,0. 1601,0.,.2 1633,6.,.2 *NGEN,NSET=FIX 1,1601,200 *NGEN,NSET=END 33,1633,200 *NFILL,NSET=MIDDLE FIX,END,16,2 *NSET,NSET=FIX,GENERATE 1,1601,200 *NSET,NSET=QA_TEST_ALLNODES FIX,END,MIDDLE *ELEMENT,TYPE=S4R 1,1,3,203,201 *ELGEN,ELSET=EALL 1,16,2,1,8,200,16 *MATERIAL,NAME=A1 *ELASTIC 1.E8,0. *DENSITY 0.25 *SHELL SECTION,MATERIAL=A1,ELSET=EALL,CONTROLS=HGLASS .01, *SECTION CONTROLS,NAME=HGLASS,HOURGLASS=ENHANCED *AMPLITUDE,NAME=LOAD,DEFINITION=SMOOTH STEP 0.0,0.0,0.1,1.0 *STEP *DYNAMIC,EXPLICIT ,0.2 *BULK VISCOSITY 0.0,0.0 *BOUNDARY FIX,1,6 MIDDLE,3,5 END,3,5 *CLOAD,AMPLITUDE=LOAD 33,2,-.125 433,2,-.25 833,2,-.25 1233,2,-.25 1633,2,-.125 *OUTPUT,FIELD,NUMBER INTERVAL=3 *ELEMENT OUTPUT S,E *NODE OUTPUT U, *OUTPUT,HISTORY,TIME INTERVAL=2e-3 *NODE OUTPUT, NSET=FIX RF2 *NODE OUTPUT,NSET=END U2 *ENERGY OUTPUT ALLAE,ALLCD,ALLKE,ALLIE,ALLWK,ETOTAL,ALLSE ********************************** ** OUTPUT FOR ABAQUS QA PURPOSES ********************************** *OUTPUT, FIELD, NUMBER INTERVAL=4, TIMEMARKS=YES *NODE OUTPUT, NSET=QA_TEST_ALLNODES U, *FILE OUTPUT,NUMBER INTERVAL=4, TIMEMARKS=YES *NODE FILE,NSET=QA_TEST_ALLNODES U *END STEP