*HEADING CANTILEVER WITH CONTINUUM ELEMENTS--END SHEAR, CPS4R, 1 X 4 MESH EXPLICIT ANALYSIS WITH ENHANCED HOURGLASS CONTROL *PREPRINT,MODEL=YES,ECHO=NO,HISTORY=YES *NODE 1,0.,0.,0. 5,6.,0.,0. 101,0.,0.2,0. 105,6.,0.2,0. *NSET,NSET=FIX1 1,101 *NSET,NSET=FREE1 5,105 *NFILL,NSET=MIDDLE FIX1,FREE1,4 *NSET,NSET=SL1 5,105 *NSET,NSET=QA_TEST_ALLNODES FIX1,FREE1,MIDDLE *ELEMENT,TYPE=CPS4R,ELSET=EALL 1, 1,2,102,101 *ELGEN,ELSET=EALL 1,4,1,1,1,100,100 *MATERIAL,NAME=STEEL *ELASTIC 1E8,0. *DENSITY 0.25 *SOLID SECTION,MATERIAL=STEEL,ELSET=EALL,CONTROLS=HGLASS 0.01 *SECTION CONTROLS,NAME=HGLASS,HOURGLASS=ENHANCED *AMPLITUDE,NAME=LOAD,DEFINITION=SMOOTH STEP 0.0,0.0,0.1,1.0 *STEP *DYNAMIC,EXPLICIT ,0.2 *BULK VISCOSITY 0.0,0.0 *BOUNDARY,TYPE=DISPLACEMENT FIX1,1,2 *CLOAD,AMPLITUDE=LOAD SL1,2,-0.5 *OUTPUT,FIELD,NUMBER INTERVAL=3 *ELEMENT OUTPUT S,E *NODE OUTPUT U, *OUTPUT,HISTORY,TIME INTERVAL=2e-3 *NODE OUTPUT, NSET=FIX1 RF2 *NODE OUTPUT,NSET=FREE1 U2 *ENERGY OUTPUT ALLAE,ALLCD,ALLKE,ALLIE,ALLWK,ETOTAL,ALLSE ********************************** ** OUTPUT FOR ABAQUS QA PURPOSES ********************************** *OUTPUT, FIELD, NUMBER INTERVAL=4, TIMEMARKS=YES *NODE OUTPUT, NSET=QA_TEST_ALLNODES U, *FILE OUTPUT,NUMBER INTERVAL=4, TIMEMARKS=YES *NODE FILE,NSET=QA_TEST_ALLNODES U *END STEP