The output variables described below are not available for random response analysis. Record format: records written for any section file output request 1580
Output request definition
1581
Section output header record
For all analysis typesThe following two records are generated only when section output is requested in a local coordinate system. In that case all components of forces and moments are given with respect to the local system. Only the first two directions of the local coordinate system are given; if needed, the third direction can be calculated as the cross product of the first two. 1582Global coordinates of the anchor point
1583
Direction cosines of the local coordinate system
1584 SOAREA Area of the defined section
For stress/displacement analyses 1585 SOF Total force in the section in the selected
system
1586 SOM Total moment in the section about the origin of the
selected system
1587 SOCF Global coordinates of the center of the total force
in the section
For heat transfer analyses 1588 SOH Total heat flux across the section
For electrical analyses 1589 SOE Total current across the section
For mass diffusion analyses 1590 SOD Total mass flow across the section
For coupled pore fluid diffusion-stress analysesFor coupled analyses the appropriate combination of records is available. For example, in a thermal-electrical analysis both SOH and SOE are valid output requests. 1591 SOP Total pore fluid volume flux across the section
|