ProductsAbaqus/StandardAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAEStep module
Required parameters
- TYPE
-
Set TYPE=QUASI-NEWTON to specify a quasi-Newton solution method.
Set TYPE=SEPARATED to specify that linearized equations for the individual fields
in a fully coupled procedure are to be decoupled and solved separately for each
field. This option can be specified only with the
COUPLED THERMAL-ELECTRICAL procedure
and the
COUPLED TEMPERATURE-DISPLACEMENT
procedure without the ELECTRICAL parameter.
Set TYPE=LCP CONTACT to activate the linearized contact capability to solve for
contact status and contact stresses. This option can be specified only within a
static perturbation step with small sliding, frictionless contact.
Optional parameters
- REFORM KERNEL
-
This parameter can be used only with TYPE=QUASI-NEWTON. Set this parameter equal to the number of quasi-Newton
iterations allowed before the kernel matrix is reformed. The default is REFORM KERNEL=8.
Data line for TYPE=LCP CONTACT
- First (and
only) line
-
Initial gap distance to specify a zone within which potential contact
constraints are exposed to the LCP solver. In the case of multiple contact
pairs, this global setting applies to all of them. By default, a gap distance
is calculated internally for each contact pair based on a characteristic facet
size associated with the contact pair.
-
Scale factor for the initial gap distance specified in the previous entry or
the internally computed (contact) pair-wise gap distances. The default is 1.0.