*PIEZOELECTRIC DAMPING

Specify piezoelectric material damping for a piezoelectric material.

This option is used to provide piezoelectric material damping for mode-based analyses and for direct-integration steady-state analysis in Abaqus/Standard.

It is relevant only for piezoelectric elements. You can provide damping coefficients for the displacement (mechanical), piezoelectric coupling, and dielectric parts of the damping operator.

This option is ignored in mode-based procedures that use Lanczos or subspace iteration eigenvalue extraction that does not use the SIM architecture (FREQUENCY, EIGENSOLVER=SUBSPACE, SIM=NO).

Related Topics
In Other Guides
Material damping
About dynamic analysis procedures

ProductsAbaqus/Standard

TypeModel data

LevelPart instance

Required and mutually exclusive parameters

BETA

Use this parameter to indicate that four βi(i=1,4) factors will be read from the data line to create Rayleigh stiffness proportional damping for the displacement, piezoelectric coupling, and dielectric parts of the damping operator in the following procedures:

STRUCTURAL

Use this parameter to indicate that four si  (i=1,4) factors will be read from the data line to create stiffness proportional structural damping for the displacement, piezoelectric coupling, and dielectric parts of the damping operator in the following procedures:

Data lines to define temperature-dependent stiffness proportional Rayleigh damping

First line
  1. β1. Damping coefficient for the displacement part of the damping operator. (Units of T.)

  2. β2. Damping coefficient for the dielectric part of the damping operator. (Units of T.)

  3. β3. Damping coefficient for the piezoelectric coupling (displacement/dielectric) part of the damping operator. (Units of T.)

  4. β4. Damping coefficient for the piezoelectric coupling (dielectric/displacement) part of the damping operator. (Units of T.)

  5. Temperature.

Repeat this data line as often as necessary.

Data lines to define temperature-dependent stiffness proportional structural damping

First line
  1. s1. Damping coefficient for the displacement part of the damping operator.

  2. s2. Damping coefficient for the dielectric part of the damping operator.

  3. s3. Damping coefficient for the piezoelectric coupling (displacement/dielectric) part of the damping operator.

  4. s4. Damping coefficient for the piezoelectric coupling (dielectric/displacement) part of the damping operator.

  5. Temperature.

Repeat this data line as often as necessary.