ProductsAbaqus/StandardAbaqus/CAE
TypeHistory data
LevelStep
Abaqus/CAELoad module
Optional parameters
- ORIENTATION
-
Set this parameter equal to the name given to the
ORIENTATION definition (Orientations)
that specifies the orientation of the local system for rigid body degrees of
freedom.
Optional, mutually exclusive parameters
- FIXED
-
Include this parameter (default in a dynamic or buckling analysis) to
indicate that the inertia relief load from a previous step should remain fixed
at its value from the beginning of the current step.
- REMOVE
-
Include this parameter to indicate that the inertia relief load from a
previous step should be removed in the current step.
Optional data
lines to specify global (or local, if the ORIENTATION parameter is used) degrees of freedom that define the free
directions along which inertia relief loads are applied
- First line
-
-
Integer list of degrees of freedom identifying the free directions.
- Second line (only needed to define a reference point for the
rigid body direction vectors when the user-chosen combination of free
directions requires such a point)
-
Global X-coordinate of the reference point.
-
Global Y-coordinate of the reference point.
-
Global Z-coordinate of the reference point.
These data lines are needed
only if rigid body motions are constrained in some
directions.
There are no data lines when the FIXED or REMOVE parameters are
specified