ProductsAbaqus/Explicit TypeModel data
LevelPartPart instance
Required parameters
- DENSITY
-
This parameter applies only to DEM
analyses.
Set this parameter equal to a numerical value or to the name of a
distribution (see
Distribution definition)
to be used with these elements.
- ELSET
-
Set this parameter equal to the name of the element set containing the
elements for which the section is being defined.
- SHAPE
-
This parameter is used to specify the shape of the discrete element.
Set this parameter equal to SPHERE (default).
Optional parameters
- ALPHA
-
Set this parameter equal to the value of the mass proportional damping
factor for discrete elements. The default value is 0.0.
- CONTROLS
-
Set this parameter equal to the name of a section controls definition (see
Section controls)
to be used to specify the size of the particle tracking box.
Data line
for discrete elements- First
(and only) line
-
Enter the name of the distribution table or the probability density function
for the radius of the discrete elements or the value of the radius. Leave blank
when the FLUID BEHAVIOR parameter is included.
|