ProductsAbaqus/ExplicitAbaqus/CAE
TypeModel data
LevelModel
Abaqus/CAEProperty module
Optional parameters
- CRACKS
-
Set CRACKS=1 (default) to indicate that an element will be removed when any local direct cracking strain (or displacement) component reaches the failure value.
Set CRACKS=2 to indicate that an element will be removed when any two direct cracking strain (or displacement) components reach the failure value.
Set CRACKS=3 to indicate that an element will be removed when all three possible direct cracking strain (or displacement) components reach the failure value.
The value for the CRACKS parameter can only be 1 for beam or truss elements. It cannot be greater than 2 for plane stress and shell elements, and it cannot be greater than 3 for three-dimensional, plane strain, and axisymmetric elements.
- DEPENDENCIES
-
Set this parameter equal to the number of field variable dependencies included in the definition of the failure criterion, in addition to temperature. If this parameter is omitted, it is assumed that the failure criterion depends only on temperature. See Material data definition for more information.
Data lines if TYPE=STRAIN (default) is used on the BRITTLE CRACKING option
- First line
Direct cracking failure strain, .
Temperature.
First field variable.
Second field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the dependence of the postcracking behavior on temperature and other predefined field variables.
Data lines if TYPE=DISPLACEMENT or GFI is included on the BRITTLE CRACKING option
- First line
Direct cracking failure displacement, . (Units of L.)
Temperature.
First field variable.
Second field variable.
Etc., up to six field variables.
- Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six)
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the dependence of the postcracking behavior on temperature and other predefined field variables.