Create a material model as described in Defining a volumetric swelling model.”
From the menu in the Edit Material dialog box, select Ratios. A Suboption Editor appears.
Toggle on Use temperature-dependent data to define data that depend on temperature. A column labeled Temp appears in the Data table.
Click the arrows to the right of the Number of field variables field to increase or decrease the number of field variables on which the data depend.
Enter the following data in the Data table:
- r11, r22, and r33
Anisotropic swelling ratios, , , and .
- Temp
Temperature.
- Field n
Predefined field variables.
You may need to expand the dialog box to see all the columns in the Data table. For detailed information on how to enter data, see Entering tabular data.
Click OK to return to the Edit Material dialog box.
|